Reactivity Measurements on the University of Maryland Reactor by Conventional Methods and Statistical Processes and Comparison with Calculational Methods
Reactivity Measurements on the University of Maryland Reactor by Conventional Methods and Statistical Processes and Comparison with Calculational Methods
Loading...
Files
Publication or External Link
Date
1970
Authors
Zubieta, Agustin Diaz
Advisor
Duffey, Dick
Citation
DRUM DOI
Abstract
The accurate experimental determination of nuclear reactor core
physics parameters is of great importance for its safe operation. In
particular, the accurate determination and prediction of criticality
during the initial fuel loading of a nuclear reactor are essential for a
safe nuclear reactor startup. Also, the degree of subcriticality or
shutdown margin of a nuclear core with its control rods inserted is an
important parameter for the operation of a nuclear reactor throughout
the core operating lifetime. There are several methods utilized to determine both the criticality
and the shutdown margins. All of these methods depend on measuring
the response of neutron detectors and the calibration of the control rods.
However, neutron detectors respond only to the neutron flux in the cor e
in the vicinity of the nuclear detectors. During initial reactor core fuel
loading, the reactivity of the core is determined from the multiplication
of the neutrons of the startup source by the addition of nuclear fuel.
Reactivity is determined from the multiplication factor by a constant
which is related to the source-detector geometry in the core. In this research a method was studied which allowed the determination of reactivity independent of the source-detector geometry. Reactivity measurements of the 10 kw University of Maryland pool training reactor (UMR) were made by conventional methods and by a statistical process, the variance-to-mean ration method, and the results were compared with calculational methods. The theoretical method selected to determine the UMR core reactivity was based on the multigroup, multiregion, diffusion theory. The accuracy of the theoretical model was determined for the just critical UMR core. Agreement to within 0.2% ΔK/K was obtained between the control rod measured and the calculated reactivity for the UMR full core, and smaller UMR supercritical cores. The statistical technique of the variance-to-mean ratio of the number of counts for various counting gate openings, as a means to determine the degree of subcriticality, or shutdown margin, has been proven to be an effective method. A BF3, thermal neutron proportional detector, with a sensitivity of 12.1 counts/sec per n/cm2/sec, was placed inside of an eleven feet long aluminum tubing. The end of the tubing containing the detector was inserted in the center Glory Hole of the UMR core. The current pulses from the proportional detector was amplified and fed to a TMC 1024-channel pulse analyzer. The pulses were counted for different Δt gate openings from 10-4 seconds to 10 seconds. For each Δt gate opening, 1023 samples were taken. The printed output from the TMC-1024 was collected, giving the number of counts received per Δt, as well as the integral of all the counts received during a period of time, equal to 1023 x Δt seconds. From the integrated value for the number of counts the average count c for the gate opening Δt was obtained. The printed output was transferred to IBM cards acceptable to a "Reactor Noise" code written for the IBM-7090. This code calculated
the average value, c, for each Δt (which gave a check on the validity
of the data transferred to the IBM cards by comparing it with the value
obtained during the measurement), the standard deviation o, and the
variance-to-mean ratio for all the data taken for each Δt seconds gate
opening. Plots of the values of the variance-to-mean ratio versus gate
openings were obtained for several UMR full core with the rods banked
at various degrees of insertion (shutdown margins), and also for various
UMR subcritical cores. Measurements of the shutdown margins by the variance-to-mean
technique were in agreement with the values obtained from the rod
calibration for negative reactivities of less than -1. 00% ΔK/K, and
within ten percent for negative reactivities of approximately -2. 0% ΔK/K. Measurements of the reactivity of small UMR cores indicated that
for UMR core conditions of 0. 5% ΔK/K subcritical, experiment and
theory for 1-Keff were found to be only 6 parts in 100 apart, and for
2. 0% ΔK/K subcritical, experiment and theory were found to be only
8 parts in 100 apart. The variance-to-mean technique was compared to the inverse
multiplication method for determination of criticality during the UMR
fuel loading, and was found to be a more accurate method, primarily,
because of its independence of the source-detector geometry effects.
The system utilized for the statistical data processing is exact,
however cumbersome, due to the amount of data to process and the
amount of peripheral hardware utilized in the reduction of the data. It appears from this study that greater overall counting efficiency
for the same amount of statistical data would permit more accurate
measurements at larger degrees of subcriticality, perhaps, in the
region of -4. 0% ΔK / K to -5. 0% ΔK / K . A system is proposed in this
study to measure negative reactivity continuously, and directly, by
means of a small computer capable of accepting the output of a multichannel scaler. The computer would have a fixed internal logic capable
of calculating reactivity from the variance-to-mean analysis of the
neutron detector counts.