The Binding Effect of Proteins on Medications and Its Impact on Electrochemical Sensing: Antipsychotic Clozapine as a Case Study

dc.contributor.authorBanis, George E.
dc.contributor.authorWinkler, Thomas
dc.contributor.authorBarton, Patricia
dc.contributor.authorChocron, Sheryl E.
dc.contributor.authorKim, Eunkyoung
dc.contributor.authorKelly, Deanna L.
dc.contributor.authorPayne, Gregory F.
dc.contributor.authorBen-Yoav, Hadar
dc.contributor.authorGhodssi, Reza
dc.date.accessioned2017-09-05T15:23:32Z
dc.date.available2017-09-05T15:23:32Z
dc.date.issued2017-08-01
dc.descriptionPartial funding for Open Access provided by the UMD Libraries' Open Access Publishing Fund.en_US
dc.description.abstractClozapine (CLZ), a dibenzodiazepine, is demonstrated as the optimal antipsychotic for patients suffering from treatment-resistant schizophrenia. Like many other drugs, understanding the concentration of CLZ in a patient’s blood is critical for managing the patients’ symptoms, side effects, and overall treatment efficacy. To that end, various electrochemical techniques have been adapted due to their capabilities in concentration-dependent sensing. An open question associated with electrochemical CLZ monitoring is whether drug–protein complexes (i.e., CLZ bound to native blood proteins, such as serum albumin (SA) or alpha-1 acid-glycoprotein (AAG)) contribute to electrochemical redox signals. Here, we investigate CLZ-sensing performance using fundamental electrochemical methods with respect to the impact of protein binding. Specifically, we test the activity of bound and free fractions of a mixture of CLZ and either bovine SA or human AAG. Results suggest that bound complexes do not significantly contribute to the electrochemical signal for mixtures of CLZ with AAG or SA. Moreover, the fraction of CLZ bound to protein is relatively constant at 31% (AAG) and 73% (SA) in isolation with varying concentrations of CLZ. Thus, electrochemical sensing can enable direct monitoring of only the unbound CLZ, previously only accessible via equilibrium dialysis. The methods utilized in this work offer potential as a blueprint in developing electrochemical sensors for application to other redox-active medications with high protein binding more generally. This demonstrates that electrochemical sensing can be a new tool in accessing information not easily available previously, useful toward optimizing treatment regimens.en_US
dc.identifierhttps://doi.org/10.13016/M2KW57J4S
dc.identifier.citationPharmaceuticals 2017, 10, 69; doi:10.3390/ph10030069en_US
dc.identifier.urihttp://hdl.handle.net/1903/19744
dc.language.isoen_USen_US
dc.publisherMultidisciplinary Digital Publishing Institute (MDPI)en_US
dc.relation.isAvailableAtA. James Clark School of Engineeringen_us
dc.relation.isAvailableAtFischell Department of Bioengineeringen_us
dc.relation.isAvailableAtDigital Repository at the University of Marylanden_us
dc.relation.isAvailableAtUniversity of Maryland (College Park, MD)en_us
dc.subjectelectrochemistryen_US
dc.subjectclozapineen_US
dc.subjectalbuminen_US
dc.subjectalpha-1 acid-glycoproteinen_US
dc.subjectultrafiltrationen_US
dc.titleThe Binding Effect of Proteins on Medications and Its Impact on Electrochemical Sensing: Antipsychotic Clozapine as a Case Studyen_US
dc.typeArticleen_US

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
pharmaceuticals-10-00069-v2 (1).pdf
Size:
5.72 MB
Format:
Adobe Portable Document Format
Description: