EVALUATION OF LOW-PRESSURE WATER-BASED TRENCH DRAIN FIRE SUPPRESSION SYSTEMS IN AIRCRAFT HANGARS USING FDS MODELING

dc.contributor.advisorMilke, James Aen_US
dc.contributor.advisorTrouve, Arnauden_US
dc.contributor.authorBraddock, Sofia Leen_US
dc.contributor.departmentFire Protection Engineeringen_US
dc.contributor.publisherDigital Repository at the University of Marylanden_US
dc.contributor.publisherUniversity of Maryland (College Park, Md.)en_US
dc.date.accessioned2023-10-12T05:34:51Z
dc.date.available2023-10-12T05:34:51Z
dc.date.issued2023en_US
dc.description.abstractThe 2020 National Defense Authorization Act (NDAA) prohibition of PFAS-containing AFFF fire protection systems by 2024 has motivated the U.S. Department of Defense to study other alternatives. In this study, the current low-expansion AFFF foam fire suppression systems with trenches layout in NAVFAC facilities are modeled as water-based systems to determine the scale, coverage, and extinguishment times that can be expected from such systems. A reduced spacing of the trenches is then simulated to determine how spacing of the floor nozzles affects fire suppression and control. Additionally, a model of a previously identified floor-level low-pressure water mist nozzle with the incorporation of trenches is studied to validate its possibility of being a replacement option for the current NAVFAC systems. Each simulation consists of three components: fire model, sprinkler/water mist model, and extinction model. Each model is evaluated separately before inputting into the final simulations to determine the most accurate representation and minimize uncertainties. The final simulations with sprinkler nozzles show successful extinguishment up to 23 MW and better performance at earlier activation time and in setups with the current trench spacing. Little to no difference is observed between the two fuel spill fire scenarios at the same activation time and trench spacing. On the other hand, the low-pressure water mist systems do not meet adequate performance in the final hangar simulations.en_US
dc.identifierhttps://doi.org/10.13016/dspace/je4f-uf8i
dc.identifier.urihttp://hdl.handle.net/1903/30954
dc.language.isoenen_US
dc.subject.pqcontrolledEngineeringen_US
dc.titleEVALUATION OF LOW-PRESSURE WATER-BASED TRENCH DRAIN FIRE SUPPRESSION SYSTEMS IN AIRCRAFT HANGARS USING FDS MODELINGen_US
dc.typeThesisen_US