Computational fluid dynamics-based design and in vitro characterization of a novel pediatric pump-lung

dc.contributor.authorHan, Dong
dc.contributor.authorZhang, Jiafeng
dc.contributor.authorHe, Ge
dc.contributor.authorGriffith, Bradley P.
dc.contributor.authorWu, Zhongjun J.
dc.date.accessioned2024-06-26T17:32:41Z
dc.date.available2024-06-26T17:32:41Z
dc.date.issued2023-10-05
dc.description.abstractBackground Although extracorporeal membrane oxygenation (ECMO) has been used to provide temporary support for pediatric patients suffering severe respiratory or cardiac failure since 1970, ECMO systems specifically designed for pediatric patients, particularly for long-term use, remain an unmet clinical need. We sought to develop a new pediatric ECMO system, that is, pediatric pump-lung (PPL), consisting of a unique cylinder oxygenator with an outside-in radial flow path and a centrifugal pump. Methods Computational fluid dynamics was used to analyze the blood fluid field for optimized biocompatible and gas exchange performances in terms of flow characteristics, hemolysis, and gas transfer efficiency. Ovine blood was used for in vitro hemolysis and gas transfer testing. Results Both the computational and experimental data showed that the pressure drop through the PPL's oxygenator is significantly low, even at a flow rate of more than 3.5 L/min. The PPL showed better hemolysis performance than a commercial ECMO circuit consisting of the Quadrox-iD pediatric oxygenator and the Rotaflow pump at a 3.5 L/min flow rate and 250 mm Hg afterload pressure. The oxygen transfer rate of the PPL can reach over 200 mL/min at a flow rate of 3.5 L/min. Conclusions The PPL has the potential to provide adequate blood pumping and excellent respiratory support with minimal risk of hemolysis for a wide range of pediatric patients.
dc.description.urihttps://doi.org/10.1111/aor.14665
dc.identifierhttps://doi.org/10.13016/tv3m-is2b
dc.identifier.citationHan D, Zhang J, He Ge, Griffith BP, Wu ZJ. Computational fluid dynamics-based design and in vitro characterization of a novel pediatric pump-lung. Artif. Organs. 2024; 48: 130–140.
dc.identifier.urihttp://hdl.handle.net/1903/32745
dc.language.isoen_US
dc.publisherWiley
dc.relation.isAvailableAtA. James Clark School of Engineeringen_us
dc.relation.isAvailableAtFischell Department of Bioengineeringen_us
dc.relation.isAvailableAtDigital Repository at the University of Marylanden_us
dc.relation.isAvailableAtUniversity of Maryland (College Park, MD)en_us
dc.titleComputational fluid dynamics-based design and in vitro characterization of a novel pediatric pump-lung
dc.typeArticle
local.equitableAccessSubmissionNo

Files

Original bundle

Now showing 1 - 1 of 1
Thumbnail Image
Name:
Artificial Organs - 2023 - Han - Computational fluid dynamics%E2%80%90based design and in vitro characterization of a novel.pdf
Size:
10.53 MB
Format:
Adobe Portable Document Format