Novel Fabrication and Optimization Strategy of Microfluidic Drug Delivery Device via Direct Laser Writing and Machine Learning
Files
Publication or External Link
External Link to Data Files
Date
Authors
Advisor
Citation
DRUM DOI
Abstract
Microneedle-based microinjection systems are essential tools in biomedical research andclinical applications, including gene therapy, stem cell transplantation, and drug delivery. How- ever, conventional microneedles face critical limitations such as tip clogging, restricted diffusion, and tissue deformation during penetration. This dissertation proposes a novel fabrication and optimization strategy for microneedle arrays (MNAs) that integrates high-resolution two-photon direct laser writing (DLW) with machine learning (ML)-driven design frameworks. The research is structured around four distinct but conceptually aligned aims: (i) a foundational ML-driven framework is established to compensate for dimensional inaccuracies in customized macro-scale medical devices. This demonstrates a robust methodology for ”first-time-right” additive man- ufacturing, establishing a computational foundation with high potential for future micro-scale translation. Transitioning directly to the complexities of the micro-domain, the research ad- dresses MNA performance by: (ii) engineering anti-clogging microneedle architectures using DLW; (iii) designing hybrid DLP-DLW printed MNAs to enhance delivery uniformity; and (iv) minimizing tissue deformation through ML-guided MNA optimization.
Experimental results demonstrate the high efficacy of this multi-pronged approach. Specif-ically, the ML-driven inverse geometry compensation framework successfully achieves first-time- right manufacturing by significantly reducing dimensional deviations in patient-specific surgical guides. At the micro-scale, the novel 3D-architected microneedles successfully mitigate tip- clogging during in vivo zebrafish embryo microinjections. Furthermore, the hybrid DLP-DLW fabricated MNAs prove mechanically robust during ex vivo mouse brain penetrations, successfully delivering fluidic payloads with enhanced spatial uniformity compared to single-needle systems. Finally, the integration of finite element analysis (FEA) and Bayesian Optimization establish a powerful computational pipeline to actively minimize the force required to puncture brain tissue. Collectively, this platform enables the rapid, customizable fabrication of MNAs tailored to spe- cific anatomical and clinical constraints, offering a transformative pathway for precision-targeted therapeutic delivery.