IMPROVING NON-CONTACT TONOMETRY: A DEEP NEURAL NETWORK BASED METHOD FOR CORNEAL DEFORMATION MAPPING

dc.contributor.advisorScarcelli, Giuliano
dc.contributor.authorAckman, Moshe
dc.contributor.authorCho, Lauren
dc.contributor.authorDo, Kun
dc.contributor.authorGreen, Aaron
dc.contributor.authorKlueter, Sam
dc.contributor.authorKrakovsky, Eliana
dc.contributor.authorLin, Jonathan
dc.contributor.authorLocraft, Ross
dc.contributor.authorMuessig, James
dc.contributor.authorWu, Hongyi
dc.date.accessioned2021-05-21T15:16:52Z
dc.date.available2021-05-21T15:16:52Z
dc.date.issued2021
dc.descriptionGemstone Team CONTACTen_US
dc.description.abstractGlaucoma, a disease characterized by increased intraocular pressure (IOP), is one of the leading causes of preventable blindness worldwide. Accurate measurement of IOP is essential in monitoring glaucomatous progression in order to deliver treatment and prevent long-term vision loss. Currently, non-contact tonometry, known as an "air-puff test", is a common diagnostic method despite its inaccessibility, discomfort, high cost, and reliance on a trained professional. To improve upon these shortcomings, we designed a cheaper tonometer integrating a novel depth-mapping neural network with a custom air-puff generation system. We deformed porcine corneas with a controlled-intensity air-puff while imaging the deformation with a single stationary camera-- a contrast to the standard Scheimpflug method. From the footage, our neural network predicted a three-dimensional map of corneal deformations. The network was able to predict a general negative trend between the IOP and the corneal deformation extracted. We compared our results to accepted literature deformation values and ground truth footage, allowing us to determine that the deformation amplitudes were physically plausible. With a more robust imaging setup, we present a promising alternative to traditional IOP measurement methods. Future studies should make the simulated footage more representative of clinical conditions to increase the generalizability of the neural network. Additionally, anatomical differences between porcine and human eyes as well as corneal variability due to socio-demographic differences must be addressed for our results to be applied to clinical settings.en_US
dc.identifierhttps://doi.org/10.13016/oaut-cnbj
dc.identifier.urihttp://hdl.handle.net/1903/27071
dc.language.isoen_USen_US
dc.relation.isAvailableAtDigital Repository at the University of Maryland
dc.relation.isAvailableAtGemstone Program, University of Maryland (College Park, Md)
dc.subjectGemstone Team CONTACTen_US
dc.titleIMPROVING NON-CONTACT TONOMETRY: A DEEP NEURAL NETWORK BASED METHOD FOR CORNEAL DEFORMATION MAPPINGen_US
dc.typeThesisen_US

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
CONTACT_Thesis.pdf
Size:
10.71 MB
Format:
Adobe Portable Document Format
Description: