TWO-PHASE HEAT TRANSFER MECHANISMS WITHIN PLATE HEAT EXCHANGERS: EXPERIMENTS AND MODELING

dc.contributor.advisorKim, Junghoen_US
dc.contributor.authorSolotych, Valentinen_US
dc.contributor.departmentMechanical Engineeringen_US
dc.contributor.publisherDigital Repository at the University of Marylanden_US
dc.contributor.publisherUniversity of Maryland (College Park, Md.)en_US
dc.date.accessioned2016-06-22T05:51:35Z
dc.date.available2016-06-22T05:51:35Z
dc.date.issued2016en_US
dc.description.abstractTwo-phase flow heat exchangers have been shown to have very high efficiencies, but the lack of a dependable model and data precludes them from use in many cases. Herein a new method for the measurement of local convective heat transfer coefficients from the outside of a heat transferring wall has been developed, which results in accurate local measurements of heat flux during two-phase flow. This novel technique uses a chevron-pattern corrugated plate heat exchanger consisting of a specially machined Calcium Fluoride plate and the refrigerant HFE7100, with heat flux values up to 1 W cm-2 and flow rates up to 300 kg m-2s-1. As Calcium Fluoride is largely transparent to infra-red radiation, the measurement of the surface temperature of PHE that is in direct contact with the liquid is accomplished through use of a mid-range (3.0-5.1 µm) infra-red camera. The objective of this study is to develop, validate, and use a unique infrared thermometry method to quantify the heat transfer characteristics of flow boiling within different Plate Heat Exchanger geometries. This new method allows high spatial and temporal resolution measurements. Furthermore quasi-local pressure measurements enable us to characterize the performance of each geometry. Validation of this technique will be demonstrated by comparison to accepted single and two-phase data. The results can be used to come up with new heat transfer correlations and optimization tools for heat exchanger designers. The scientific contribution of this thesis is, to give PHE developers further tools to allow them to identify the heat transfer and pressure drop performance of any corrugated plate pattern directly without the need to account for typical error sources due to inlet and outlet distribution systems. Furthermore, the designers will now gain information on the local heat transfer distribution within one plate heat exchanger cell which will help to choose the correct corrugation geometry for a given task.en_US
dc.identifierhttps://doi.org/10.13016/M2DB7G
dc.identifier.urihttp://hdl.handle.net/1903/18242
dc.language.isoenen_US
dc.subject.pqcontrolledEngineeringen_US
dc.subject.pqcontrolledEnergyen_US
dc.subject.pquncontrolledBoilingen_US
dc.subject.pquncontrolledInfrareden_US
dc.subject.pquncontrolledLocal heat transfer measurementsen_US
dc.subject.pquncontrolledplate-and-frame heat exchangeren_US
dc.subject.pquncontrolledswirl-flow devicesen_US
dc.subject.pquncontrolledTwo-phase flowen_US
dc.titleTWO-PHASE HEAT TRANSFER MECHANISMS WITHIN PLATE HEAT EXCHANGERS: EXPERIMENTS AND MODELINGen_US