Unified Datacenter Power Management Considering On-Chip and Air Temperature Constraints

dc.contributor.advisorSrivastava, Ankur
dc.contributor.authorShi, Bing
dc.contributor.authorSrivastava, Ankur
dc.date.accessioned2010-04-26T12:43:39Z
dc.date.available2010-04-26T12:43:39Z
dc.date.issued2010
dc.description.abstractThe current approaches for datacenter power management (workload scheduling, CPU speed control, etc) focus primarily on maintaining the air temperature surrounding servers to be within the manufacturer specified constraint. This is problematic since several CPUs may still be violating the on-chip thermal constraint thereby leading to reliability loss. The primary objective of this work is to develop a unified approach for datacenter power optimization (by controlling the CPU speeds) which accounts for both the silicon level temperature of the VLSI components such as CPUs and the air temperature that directly impacts the reliability of other devices such as disks, and also the performance delivered. Our algorithm follows a two step approach: optimally solving a convex approximation that assigns continuous frequency values to all CPUs and a discretization step for legalization of the assigned frequencies. The experimental results indicate that our method guarantees both on-chip CPU and off-chip air temperature to be within temperature constraints. However, the traditional approach of constraining only air temperature will result in on-chip CPU temperature violation on about 40% of the CPUs, or 42% more power consumption to pull the CPU temperature back within constraint by increasing the HVAC cooling.en_US
dc.description.sponsorshipNSF grant CCF 0937865en_US
dc.identifier.urihttp://hdl.handle.net/1903/10060
dc.language.isoen_USen_US
dc.relation.isAvailableAtInstitute for Systems Researchen_us
dc.relation.isAvailableAtDigital Repository at the University of Marylanden_us
dc.relation.isAvailableAtUniversity of Maryland (College Park, MD)en_us
dc.relation.ispartofseriesTR_2010-8;
dc.subjectdatacenteren_US
dc.subjectpower managementen_US
dc.subjecttemperatureen_US
dc.titleUnified Datacenter Power Management Considering On-Chip and Air Temperature Constraintsen_US
dc.typeTechnical Reporten_US

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
datacenter_power_management_edited.pdf
Size:
764.91 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.8 KB
Format:
Item-specific license agreed upon to submission
Description: