DETERMINING MEASUREMENT REQUIREMENTS FOR WHOLE BUILDING ENERGY MODEL CALIBRATION

dc.contributor.advisorSrebric, Jelenaen_US
dc.contributor.authorDahlhausen, Matthew Galenen_US
dc.contributor.departmentMechanical Engineeringen_US
dc.contributor.publisherDigital Repository at the University of Marylanden_US
dc.contributor.publisherUniversity of Maryland (College Park, Md.)en_US
dc.date.accessioned2021-07-07T05:31:11Z
dc.date.available2021-07-07T05:31:11Z
dc.date.issued2020en_US
dc.description.abstractEnergy retrofits of existing buildings reduce grid requirements for new generation and reduce greenhouse gas emissions. However, it is difficult to estimate energy savings, both at the individual building and entire building stock level, because building energy models are poorly calibrated to actual building performance. This uncertainty has made it difficult to prioritize research and development and incentive programs for building technologies at the utility, state, and federal level. This research seeks to make it easier to generate building energy models for existing buildings, and to calibrate buildings at the stock level, to create accurate commercial building load forecasts. Once calibrated, these building models can be used as seeds to other building energy model calibration approaches and to help utility, state, and federal actors to identify promising energy saving technologies in commercial buildings. This research details the economics of a building energy retrofit at a singular building; contributes significantly to the development of ComStock, a model of the commercial building stock in the U.S.; identifies important parameters for calibrating ComStock; and calibrates ComStock for an example utility region of Fort Collins, CO against individual commercial building interval data. A study of retrofit costs finds that measure cost and model uncertainty are the most significant sources of variation in retrofit financial performance, followed financing cost. A wide range of greenhouse gas pricing scenarios show they have little impact on the financial performance of whole building retrofits. A sensitivity analysis of ComStock model inputs across an exhaustive range of models identifies 19 parameters that explain 80 of energy use and 25 parameters that explain 90% of energy use. Building floor area alone explains 41% of energy use. Finally, a comparison of ComStock to Fort Collins, CO interval meter data shows a 6.92% normalized mean bias error and a 16.55% coefficient of variation of root mean square error based on normalized annual energy per floor area. Improvements in meter classification and ComStock model variability will further improve model fit and provide an accurate means of modeling the commercial building stock.en_US
dc.identifierhttps://doi.org/10.13016/jzg8-i3mw
dc.identifier.urihttp://hdl.handle.net/1903/27208
dc.language.isoenen_US
dc.subject.pqcontrolledMechanical engineeringen_US
dc.subject.pquncontrolledBuilding Energy Modelingen_US
dc.subject.pquncontrolledBuildingsen_US
dc.subject.pquncontrolledCalibrationen_US
dc.subject.pquncontrolledEnergy Efficiencyen_US
dc.subject.pquncontrolledStock Modelen_US
dc.titleDETERMINING MEASUREMENT REQUIREMENTS FOR WHOLE BUILDING ENERGY MODEL CALIBRATIONen_US
dc.typeDissertationen_US

Files

Original bundle

Now showing 1 - 1 of 1
Thumbnail Image
Name:
Dahlhausen_umd_0117E_21217.pdf
Size:
10.74 MB
Format:
Adobe Portable Document Format