DEVELOPMENT OF AN INTEGRATED CAPSULE SYSTEM FOR GASTROINTESTINAL-TARGETED BIOSENSING

dc.contributor.advisorGhodssi, Rezaen_US
dc.contributor.authorBanis, George Efstratiosen_US
dc.contributor.departmentBioengineeringen_US
dc.contributor.publisherDigital Repository at the University of Marylanden_US
dc.contributor.publisherUniversity of Maryland (College Park, Md.)en_US
dc.date.accessioned2020-02-01T06:35:25Z
dc.date.available2020-02-01T06:35:25Z
dc.date.issued2019en_US
dc.description.abstractNon-invasive microsystems are emerging as a means to address diagnostics challenges in healthcare due to the potential to retrieve information at the source and in a personalized approach. The gastrointestinal (GI) tract is a hub of information that alters in composition during both homeostatic and pathological conditions, and often manifests as varying biochemical concentrations in cell and tissue-sourced secretions. Thus, innovative strategies to sample molecular information from these secretions would be of significant benefit to physicians in establishing an appropriate prognosis. This dissertation describes the development of a film-based capacitive sensing strategy and subsequent integration into a capsule-based microsystem that is designed to travel through the GI tract upon ingestion until it passes through the stomach, where it is designed to measure model analytes in duodenal secretions. Subsequently, the measurements are processed into signals for wireless transmission, enabling external analysis for potential clinical utility. To achieve a system that can be safely ingested by patients, design features must be implemented that follow previously established standards in device requirements such as geometry and biocompatibility. In this work, I aid in the design, integration, and characterization of a capsule-embedded sensing system using commercial off-the-shelf components that interface capacitive transducers (range: 0.8-220 pF; sensitivity: 7.3x10-3) with a smart phone via Bluetooth Low Energy (2.4 GHz). The transducers are designed to measure the change in dielectric constant of interfacing media, which transitions when specific environmental (pH) characteristics are met. The system, including the power supply, are manufactured on a printed circuit board and packaged within a 3D-printed capsule structure (13 mm x 35 mm) that maintains dimensions of other clinically utilized ingestible capsule devices. The system is cost effective, user-friendly, biocompatible, and can serve as a highly customizable platform for measuring a variety of desired targets. Secretions from various GI organs can be distinguished by pH, as is demonstrated in the pharmaceutical industry via enteric coatings that dissolve in target pH ranges but maintain structural stability in others. I employ such coatings for protecting our system until targeting the pH, and therefore GI region, of interest for sampling. Once dissolved, microfluidic inlets allow access for the media to interface with the sensors. I studied coatings that respond to both acidic (<pH 3) and neutral conditions (>pH 6), as well as pH sequences via hierarchical coatings. Because the target analytes react with naturally occurring substrates, I investigate label-free sensing of model enzymes such as pancreatic trypsin (20-40 μM) and lipase (10 μM-1 mM), as well as bile salts (0.07-7 %w/v) as a model emulsifier, using films composed of biomaterials, including gelatin and stearin. To integrate these materials with the desired microsystem, I investigate various film deposition and modification strategies. Studies performed with our platform suggest the potential for the ability to sample the target fluid, as well as sense the analyte of interest in different concentrations by comparing the rate of capacitance change upon fluid entry compared to uncoated controls. Using this system, I characterize its potential for utility as a non-invasive platform for targeting multiple GI regions and detecting sensor-compatible biomarkers.en_US
dc.identifierhttps://doi.org/10.13016/jkqf-fbhv
dc.identifier.urihttp://hdl.handle.net/1903/25399
dc.language.isoenen_US
dc.subject.pqcontrolledBioengineeringen_US
dc.subject.pqcontrolledElectrical engineeringen_US
dc.subject.pquncontrolledCapsuleen_US
dc.subject.pquncontrolledDiagnosticsen_US
dc.subject.pquncontrolledGastrointestinalen_US
dc.subject.pquncontrolledIngestibleen_US
dc.subject.pquncontrolledPancreasen_US
dc.subject.pquncontrolledSystem Integrationen_US
dc.titleDEVELOPMENT OF AN INTEGRATED CAPSULE SYSTEM FOR GASTROINTESTINAL-TARGETED BIOSENSINGen_US
dc.typeDissertationen_US

Files

Original bundle
Now showing 1 - 3 of 3
Loading...
Thumbnail Image
Name:
Banis_umd_0117E_20387.pdf
Size:
6.81 MB
Format:
Adobe Portable Document Format
Loading...
Thumbnail Image
Name:
RightsLink Printable License_11.pdf
Size:
152.91 KB
Format:
Adobe Portable Document Format
Loading...
Thumbnail Image
Name:
RightsLink Printable License_12.pdf
Size:
97.37 KB
Format:
Adobe Portable Document Format