How Violent Are Fast Controls?

dc.contributor.authorSeidman, T.I.en_US
dc.contributor.departmentISRen_US
dc.date.accessioned2007-05-23T09:37:05Z
dc.date.available2007-05-23T09:37:05Z
dc.date.issued1987en_US
dc.description.abstractConsider acontrollable system: x = Ax + Bu, with x(0) = 0. Given any time T > 0 there is then a control operator C_T : EPSILON --> U(DOT) giving the (unique) minimum norm control such that x(T) = EPSILON. We show that ||C_T|| ~ LAMBDA T ^(-(K+1/2)) where LAMBDA is computable from A, B and K is the minimal exponent giving the rank condition.en_US
dc.format.extent269897 bytes
dc.format.mimetypeapplication/pdf
dc.identifier.urihttp://hdl.handle.net/1903/4559
dc.language.isoen_USen_US
dc.relation.ispartofseriesISR; TR 1987-51en_US
dc.titleHow Violent Are Fast Controls?en_US