Parametric Limitations on Discharge Performance in the Maryland Centrifugal Experiment

dc.contributor.advisorEllis, Richard Fen_US
dc.contributor.authorLunsford, Robert A.en_US
dc.contributor.departmentPhysicsen_US
dc.contributor.publisherDigital Repository at the University of Marylanden_US
dc.contributor.publisherUniversity of Maryland (College Park, Md.)en_US
dc.date.accessioned2007-06-22T05:33:03Z
dc.date.available2007-06-22T05:33:03Z
dc.date.issued2007-04-18
dc.description.abstractInherent in any experiment is a set of bounding limitations. In the Maryland Centrifugal eXperiment (MCX) these limitations are manifest as restrictions upon discharge performance as defined by program goals. We therefore examine the multidimensional parameter space in which MCX operates so as to ascertain the performance boundaries along each of the variable axes. In as much as is possible, the variables are expressly decoupled in order to determine their unique effect upon discharge performance. This study has led to the following conclusions. First, the nascent cause of transitions within the MCX discharge from a higher voltage mode (H-mode) into a lower voltage mode (O-mode) appears to be consistent with the formation of a secondary breakdown within the vacuum vessel. These transitions have been shown to be mitigated by auspicious choice of insulator position and geometry. Second, the effect of variations to the radial extent of the discharge has been studied and a set of parametric dependencies determined. These show the MCX discharge to be diffusive in nature, and highly dependant upon radial extent. Thus leading to the conclusion that a minor increase to the midplane vessel extent should result in substantial performance enhancement. Finally, a global limitation to the MCX discharge has been discovered. It is manifest as an abrupt maximum attainable voltage across the plasma. This has been interpreted as a velocity limitation due to the direct relationship between plasma voltage and rotation velocity (v(phi) = Vp/aB). An examination of a discharge struck in a background helium environment, as opposed to the standard hydrogen backfill, has shown that this limit is consistent with Alfven's theory of a critical ionization velocity. While this limitation has been observed on the historic predecessors to MCX, there have also been cases where supercritical velocities have been achieved. Suggestions for facilitating access to this regime as well as projections for an enhanced iteration of the MCX device are listed.en_US
dc.format.extent2646667 bytes
dc.format.mimetypeapplication/pdf
dc.identifier.urihttp://hdl.handle.net/1903/6751
dc.language.isoen_US
dc.subject.pqcontrolledPhysics, Fluid and Plasmaen_US
dc.subject.pquncontrolledrotating plasmaen_US
dc.subject.pquncontrolledMCXen_US
dc.subject.pquncontrolledLunsforden_US
dc.subject.pquncontrolledCritical Ionization Velocityen_US
dc.subject.pquncontrolledCIVen_US
dc.titleParametric Limitations on Discharge Performance in the Maryland Centrifugal Experimenten_US
dc.typeDissertationen_US

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
umi-umd-4231.pdf
Size:
2.52 MB
Format:
Adobe Portable Document Format