Skip to content
University of Maryland LibrariesDigital Repository at the University of Maryland
    • ログイン
    アイテム表示 
    •   ホーム
    • Theses and Dissertations from UMD
    • UMD Theses and Dissertations
    • アイテム表示
    •   ホーム
    • Theses and Dissertations from UMD
    • UMD Theses and Dissertations
    • アイテム表示
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    One-Dimensional Analytical Model Development of a Plasma-Based Actuator

    Thumbnail
    閲覧/開く
    Popkin_umd_0117E_15114.pdf (15.79Mb)
    No. of downloads: 917

    日付
    2014
    著者
    Popkin, Sarah Haack
    Advisor
    Flatau, Alison B
    Metadata
    アイテムの詳細レコードを表示する
    抄録
    This dissertation provides a method for modeling the complex, multi-physics, multi-dimensional processes associated with a plasma-based flow control actuator, also known as the SparkJet, by using a one-dimensional analytical model derived from the Euler and thermodynamic equations, under varying assumptions. This model is compared to CFD simulations and experimental data to verify and/or modify the model where simplifying assumptions poorly represent the real actuator. The model was exercised to explore high-frequency actuation and methods of improving actuator performance. Using peak jet momentum as a performance metric, the model shows that a typical SparkJet design (1 mm orifice diameter, 84.8 mm<super>3</super> cavity volume, and 0.5 J energy input) operated over a range of frequencies from 1 Hz to 10 kHz shows a decrease in peak momentum corresponding to an actuation cutoff frequency of 800 Hz. The model results show that the cutoff frequency is primarily a function of orifice diameter and cavity volume. To further verify model accuracy, experimental testing was performed involving time-dependent, cavity pressure and arc power measurements as a function of orifice diameter, cavity volume, input energy, and electrode gap. The cavity pressure measurements showed that pressure-based efficiency ranges from 20% to 40%. The arc power measurements exposed the deficiency in assuming instantaneous energy deposition and a calorically perfect gas and also showed that arc efficiency was approximately 80%. Additional comparisons between the pressure-based modeling and experimental results show that the model captures the actuator dependence on orifice diameter, cavity volume, and input energy but over-estimates the duration of the jet flow during Stage 2. The likely cause of the disagreement is an inaccurate representation of thermal heat transfer related to convective heat transfer or heat loss to the electrodes.
    URI
    http://hdl.handle.net/1903/15455
    Collections
    • Aerospace Engineering Theses and Dissertations
    • UMD Theses and Dissertations

    DRUM is brought to you by the University of Maryland Libraries
    University of Maryland, College Park, MD 20742-7011 (301)314-1328.
    Please send us your comments.
    Web Accessibility
     

     

    ブラウズ

    リポジトリ全体コミュニティ/コレクション公開日著者タイトル主題このコレクション公開日著者タイトル主題

    登録利用者

    ログイン登録
    Pages
    About DRUMAbout Download Statistics

    DRUM is brought to you by the University of Maryland Libraries
    University of Maryland, College Park, MD 20742-7011 (301)314-1328.
    Please send us your comments.
    Web Accessibility