Noninvasive Cleaning and Sanitation Monitoring System for Deli Department Processing

Loading...
Thumbnail Image

Files

Publication or External Link

Date

2013

Citation

DRUM DOI

Abstract

The inability to adequately judge the efficacy of cleaning/sanitation in deli departments is a recognized food safety concern. In prior studies, our research group demonstrated that visual inspection of cleaned produce processing surfaces could be enhanced through the use of a portable imaging device. To explore the feasibility of using this technology to facilitate detection of deli residues, fluorescence spectra of deli commodities were acquired using a laboratory-based hyperspectral imaging system. Cheeses evidenced a strong response at 675 nm; meats were best detected at 475 or 520 nm, demonstrating these wavelengths are good candidates for deli residue detection. To confirm these findings, images were taken of an in-house deli slicer with the portable imaging device. Deli residues were detected and several slicer areas were identified as being prone to residue buildup. Results confirmed the potential to use a portable imaging device to enhance current cleaning procedures in a deli setting.

Notes

Rights