dc.description.abstractDetermination of the 182W/184W ratio to a precision of ±5 ppm (2σ) is desirable for constraining the timing of core formation and other early planetary differentiation processes. However, WO − analysis by negative thermal ionization mass spectrometry normally results in a residual correlation between the instrumental-mass-fractionation-corrected 182W/184W and 183W/184W ratios that is attributed to mass-dependent variability of O isotopes over the course of an analysis and between different analyses. A second-order correction using the 183W/184W ratio relies on the assumption that this ratio is constant in nature. This may prove invalid, as has already been realized for other isotope systems. The present study utilizes simultaneous monitoring of the 18O/16O and W isotope ratios to correct oxide interferences on a per-integration basis and thus avoid the need for a double normalization of W isotopes. After normalization of W isotope ratios to a pair of W isotopes, following the exponential law, no residual W−O isotope correlation is observed. However, there is a nonideal mass bias residual correlation between 182W/iW and 183W/iW with time. Without double normalization of W isotopes and on the basis of three or four duplicate analyses, the external reproducibility per session of 182W/184W and 183W/184W normalized to 186W/183W is 5−6 ppm (2σ, 1−3 μg loads). The combined uncertainty per session is less than 4 ppm for 183W/184W and less than 6 ppm for 182W/184W (2σm) for loads between 3000 and 50 ng.en_US
dc.description.sponsorshipNSF EAR-CSEDI Grant 1265169en_US
dc.identifierhttps://doi.org/10.13016/mjzg-cvbc
dc.identifier.citation10.1021/acs.analchem.5b04006en_US
dc.identifier.urihttp://hdl.handle.net/1903/26948
dc.language.isoenen_US
dc.publisherACS Publicationsen_US
dc.relation.isAvailableAtCollege of Computer, Mathematical & Natural Sciencesen_us
dc.relation.isAvailableAtGeologyen_us
dc.relation.isAvailableAtDigital Repository at the University of Marylanden_us
dc.relation.isAvailableAtUniversity of Maryland (College Park, MD)en_us
dc.subjecttungsten, isotope, negative thermal ionization mass spectrometryen_US
dc.titleHigh-Precision Tungsten Isotopic Analysis by Multicollection Negative Thermal Ionization Mass Spectrometry Based on Simultaneous Measurement of W and 18O/16O Isotope Ratios for Accurate Fractionation Correctionen_US
dc.typeArticleen_US

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Trinquier et al. (2015 IJMS).pdf
Size:
358.41 KB
Format:
Adobe Portable Document Format
Description:
Accepted version of manuscript.
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.57 KB
Format:
Item-specific license agreed upon to submission
Description: