Aghilinasrollahabadi, KhashayarGhandehari, Shahrzad SaffariKjellerup, Birthe VenoNguyen, CarolineSaavedra, YermanLi, GuangbinPhosphorous (P) removal in wastewater treatment is essential to prevent eutrophication in water bodies. Side-stream enhanced biological phosphorous removal (S2EBPR) is utilized to improve biological P removal by recirculating internal streams within a side-stream reactor to generate biodegradable carbon (C) for polyphosphate accumulating organisms (PAOs). In this study, a full-scale S2EBPR system in a water resource recovery facility (WRRF) was evaluated for 5 months. Batch experiments revealed a strong positive correlation (r = 0.91) between temperature and C consumption rate (3.56–8.18 mg-COD/g-VSS/h) in the system, with temperature ranging from 14°C to 18°C. The anaerobic P-release to COD-uptake ratio decreased from 0.93 to 0.25 mg-P/mg-COD as the temperature increased, suggesting competition between PAOs and other C-consumers, such as heterotrophic microorganisms, to uptake bioavailable C. Microbial community analysis did not show a strong relationship between abundance and activity of PAO in the tested WRRF. An assessment of the economic feasibility was performed to compare the costs and benefits of a full scale WRRF with and without implementation of the S2EBPR technology. The results showed the higher capital costs required for S2EBPR were estimated to be compensated after 5 and 11 years of operation, respectively, compared to chemical precipitation and conventional EBPR. The results from this study can assist in the decision-making process for upgrading a conventional EBPR or chemical P removal process to S2EBPR.en-USAssessing the performance of polyphosphate accumulating organisms in a full-scale side-stream enhanced biological phosphorous removalArticle