    Radiation dose reduction strategies for intraoperative guidance and navigation using CT

    Thumbnail
    View/Open
    umi-umd-4171.pdf (2.674Mb)
    No. of downloads: 3734

    Date
    2007-02-20
    Author
    Shetye, Avanti Satish
    Advisor
    Shekhar, Raj
    Metadata
    Show full item record
    Abstract
    The advent of 64-slice computed tomography (CT) with high speed scanning makes CT a highly attractive and powerful tool for navigating image guided procedures. Interactive navigation needs scanning to be performed over extended time periods or even continuously. However, continuous CT is likely to expose the patient and the physician to potentially unsafe radiation levels. Before CT can be used appropriately for navigational purposes, the dose problem must be solved. Simple dose reduction is not adequate, because it degrades image quality. This study proposes two strategies for dose reduction; the first is the use of a statistical approach representing the stochastic nature of noisy projection data at low doses to lessen image degradation and the second, the modeling of local image deformations in a continuous scan. Taking advantage of modern CT scanners and specialized hardware, it may be possible to perform continuous CT scanning at acceptable radiation doses for intraoperative navigation.
    URI
    http://hdl.handle.net/1903/6699
    Collections
    • Electrical & Computer Engineering Theses and Dissertations
    • UMD Theses and Dissertations

    DRUM is brought to you by the University of Maryland Libraries
    University of Maryland, College Park, MD 20742-7011 (301)314-1328.
    Please send us your comments.
    Web Accessibility
     

     

    Browse

    All of DRUMCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister
    Pages
    About DRUMAbout Download Statistics

    DRUM is brought to you by the University of Maryland Libraries
    University of Maryland, College Park, MD 20742-7011 (301)314-1328.
    Please send us your comments.
    Web Accessibility