Skip to content
University of Maryland LibrariesDigital Repository at the University of Maryland
    • Login
    View Item 
    •   DRUM
    • A. James Clark School of Engineering
    • Institute for Systems Research Technical Reports
    • View Item
    •   DRUM
    • A. James Clark School of Engineering
    • Institute for Systems Research Technical Reports
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Real-Time Growth Rate Metrology for a Tungsten CVD Process by Acoustic Sensing

    Thumbnail
    View/Open
    TR_2000-24.pdf (161.2Kb)
    No. of downloads: 791

    Date
    2000
    Author
    Henn-Lecordier, Laurent
    Kidder, John N., Jr.
    Rubloff, Gary W.
    Gogol, C. A.
    Wajid, A.
    Metadata
    Show full item record
    Abstract
    An acoustic sensor, the Leybold Inficon ComposerTM, was implemented downstream to a production-scale tungsten chemical vapor deposition (CVD) cluster tool for in-situ process sensing. Process gases were sampled at the outlet of the reactor chamber and compressed with a turbo-molecular pump and mechanical pump from the sub-Torr process pressure regime to above 50 Torr as required for gas sound velocity measurements in the acoustic cavity. The high molecular weight gas WF6 mixed with H2 provides a substantial molecular weight contrast so that the acoustic sensing method appears especially sensitive to WF6 concentration. <p>By monitoring the resonant frequency of exhaust process gases, the depletion of WF6 resulting from the reduction by H2 was readily observed in the 0.5 Torr process for wafer temperatures ranging from 300 to 350 C. Despite WF6 depletion rates as low as 3-5%, in-situ wafer-state metrology was achieved with an error less than 6% over 17 processed wafers. <p>This in-situ metrology capability combined with accurate sensor response modeling suggests an effective approach for acoustic process sensing in order to achieve run-to-run process control of the deposited tungsten film thickness.
    URI
    http://hdl.handle.net/1903/6132
    Collections
    • Institute for Systems Research Technical Reports

    DRUM is brought to you by the University of Maryland Libraries
    University of Maryland, College Park, MD 20742-7011 (301)314-1328.
    Please send us your comments.
    Web Accessibility
     

     

    Browse

    All of DRUMCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister
    Pages
    About DRUMAbout Download Statistics

    DRUM is brought to you by the University of Maryland Libraries
    University of Maryland, College Park, MD 20742-7011 (301)314-1328.
    Please send us your comments.
    Web Accessibility