A. James Clark School of Engineering
Permanent URI for this communityhttp://hdl.handle.net/1903/1654
The collections in this community comprise faculty research works, as well as graduate theses and dissertations.
Browse
2 results
Search Results
Item NANOTUBE-MATRIX INTERPLAY AND TUNABILITY IN ULTRAHIGH VOLUME-FRACTION ALIGNED CARBON NANOTUBE POLY(URETHANE-UREA) NANOCOMPOSITES(2017) Gair, Jeffrey Lynn; Bruck, Hugh A.; Mechanical Engineering; Digital Repository at the University of Maryland; University of Maryland (College Park, Md.)The present dissertation seeks to better understand the nature of biphasic poly(urethane-urea) (PUU) interactions in materials with densely packed, aligned carbon nanotubes (CNTs). Of particular interest are the CNT-matrix interactions with in-situ polymerized PUU of various stoichiometric ratios. A novel synthesis method for PUU which permits fabrication of PUU-based polymer nanocomposites (PNCs) has been developed. Study of the thermal and multiscale mechanical behavior of stoichiometrically varied PUU materials has been conducted to demonstrate significant interaction between the matrix and CNTs, both in terms of morphology and mechanical reinforcement. PNCs with CNT Vf up to 30% have been achieved with excellent wetting confirmed via Micro-CT. TGA and DSC have revealed that CNTs stabilize thermal degradation of PUU by inducing crystallinity and reducing phase-mixing. AFM confirmed this by visualizing the crystals present in the matrix materials. CNT-induced crystallinity and phase-separation are attributed to the binding of CNTs to hard segments, which limit chain mobility during polymerization. Higher CNT Vf PNCs were found to increase soft-segment crystallinity, though with diminishing returns. Extreme crystallinity was found at 10% Vf CNTs which is though to arise due to an optimized spacing to permit ordered crystal formation of the PUU. Enhancements to indentation modulus of up to 1600% in the transverse orientation and 3500% in the axial orientation have been recorded via quasi-static nanoindentation. Greater CNT Vf and greater hard-segment composition lead to reduced chain mobility, and in some instances, can reduce CNT effectiveness in mechanical enhancement. The 10% CNT Vf exhibits greater indentation and storage moduli arising which is thought to arise from an optimized balance of inter-CNT spacing and chain mobility. Furthermore, PUU with higher hard-segment content is highly anisotropic and highly rate-sensitive, indicating significant morphological interactions with inter-CNT spacing of ~18nm. Degradation and increased loss modulus are seen in similar PUU with 20% loading, pointing to weak chain interactions and reduced hydrogen, likely do to confinement and reduced mobility. A model has also been developed which sheds light on the evolution of CNT-matrix interactions across a wide range of CNT volume-fractions.Item SIZE MODIFICATION AND COATING OF TITANIUM DIOXIDE USING A PREMIXED HYDROGEN/AIR FLAME(2006-08-22) Lee, Seungchan; Ehrman, Sheryl H; Chemical Engineering; Digital Repository at the University of Maryland; University of Maryland (College Park, Md.)A study was conducted of the effect of flame processing on the size distribution of titania nanoparticles, and a flame process was developed for producing TiO2/SiO2 coreshell particles from aqueous suspensions of TiO2 and SiO2 nanoparticles. Both were performed using a premixed hydrogen/air flame. At the adiabatic flame temperature of 2400 K, the number mean diameter of titania primary particle increased considerably from an initial value of 44 nm to 96 nm, presumably by atomic diffusion, and viscous flow coalescence. Moreover, the majority of product particles from this high flame temperature were smooth and spherical. Based on the results of size modification experiments, coating experiments were performed. The dominant morphology observed in the product particles from coating experiments was silica coated titania. The silica coating was very smooth and dense. The total particle size and the shell volume of the product particles were in reasonable agreement with values predicted from the atomized droplet size distribution and the droplet concentration.