This Diagnostic_Devices_README.txt file was generated on 20240813 by Victoria Castagna Ferrari


-------------------
GENERAL INFORMATION
-------------------


1. Title of Dataset: Interface Diagnostics Platform for Thin-Film Solid-State Batteries


2. Author Information:


    Principal Investigator Contact Information:
        
	Name: David M. Stewart
        Institution: University of Maryland
        Address: College Park, MD 20742
        Email: steward@umd.edu


    Associate or Co-investigator Contact Information:
        
	Name: Victoria Castagna Ferrari
        Institution: University of Maryland
        Address: College Park, MD 20742
        Email: ferrariv@umd.edu



3. Date of data collection: 20220520 - 20221222


4. Geographic location of data collection: University of Maryland, College Park, MD, United States


5. Information about funding sources that supported the collection of the data:
This work was supported by the U.S. Department of Energy, Office of Science, Office of Basic Energy Sciences, under Grant DE-SC0021070.



---------------------
DATA & FILE OVERVIEW
---------------------


1. Folder List:


    A. Al-LiPON-Cu:
        raw data of electrical measurements using the Al-LiPON-Cu diagnostic device: Potentio-Electrochemical Impedance Spectroscopy (PEIS) and Staircase Potentio-Electrochemical Impedance Spectroscopy (SPEIS) experiments. This folder also contains fitting parameters of electric circuit model and the properties calculated based on those parameters.


    B. Al-LiPON-Si-Cu:
        raw data of electrical measurement using the Al-LiPON-Si-Cu diagnostic device: PEIS experiment. This folder also contains fitting parameters of electric circuit model and the properties calculated based on those parameters.


    C. Al-LVO-Cu:
        raw data of electrical measurement using the Al-LVO-Cu diagnostic device: PEIS experiment. This folder also contains fitting parameters of electric circuit model and the properties calculated based on those parameters.


    D. Al-LVO-LiPON-Cu:
        raw data of electrical measurements using the Al-LVO-LiPON-Cu diagnostic device: PEIS, SPEIS and Cyclic Voltammetry (CV) experiments. This folder also contains fitting parameters of electric circuit model and the properties calculated based on those parameters.


    E. Al-LVO-LiPON-Si-Cu:
        raw data of electrical measurements using the Al-LVO-LiPON-Si-Cu diagnostic device: PEIS, SPEIS, CV and Galvanostatic Cycling with Potential Limitation (GCPL) experiments. This folder also contains fitting parameters of electric circuit model and the properties calculated based on those parameters.


    F. Al-Si-Cu:
        raw data of electrical measurement using the Al-Si-Cu diagnostic device: PEIS experiment. This folder also contains fitting parameters of electric circuit model and the properties calculated based on those parameters.



2. Relationship between files:

	This repository is organized such that each separate folder contains text files that
were directly extracted from experimental procedures. The levels of folders are:

	- Level 1: device type that was experimentally measured (eg. Al-XXXX-Cu_device)
	- Level 2: type of experimental technique of the raw data (eg. PEIS, CV) and/or fitting parameters extracted from electric circuit models
	- Level 3 (if necessary): specifications of the experimental technique (eg. voltage
increase/voltage decrease)


	As an example, raw data of the impedance response as a function of frequency of the 
Al-LiPON-Cu device taken at 1080 mV during an increase voltage ramp can be found at
the following repository path:

Al-LiPON-Cu\SPEIS\Al-LiPON-Cu_SPEIS - voltage increaseAl-LiPON-Cu_SPEIS_voltage_increase_1080mV_cycle7.txt



3. Are there multiple versions of the dataset? No



--------------------------
METHODOLOGICAL INFORMATION
--------------------------


1. Description of methods used for collection/generation of data: 

Electrical measurements were taken using a probe station inside an Argon-filled glovebox. For every measured device, the counter/reference electrode was the copper contact, while the working electrode was the copper contact. 


2. Instrument- or software-specific information needed to interpret the data:
A potentiostat (BioLogic, SP-300) was used to perform the electrical measurements, and Ec-lab was the software used to export the acquired data to text files.

All data presented in this repository can be opened using a text reader.


3. Standards and calibration information, if appropriate:
Area of every measured device: 0.15 cm^2
Mass of cathode electrode: 18.1 micrograms


4. Describe any quality-assurance procedures performed on the data:
Materials used in the fabrication process were previously developed by the authors. Replicates of complete devices (Al-LVO-LiPON-Si-Cu device) were tested to ensure reproducibility of the charge-discharge profile.


5. People involved with sample collection, processing, analysis and/or submission:
Victoria c. Ferrari, Department of Materials Science and Engineering, University of Maryland
Sang Bok Lee, Department of Chemistry, University of Maryland
Gary W. Rubloff, Department of Materials Science and Engineering, University of Maryland
David M. Stewart, Department of Materials Science and Engineering, University of Maryland