Quantitative and Qualitative Trade-Off Analysis of Drowsy Driver Detection Methods: Single Electrode Wearable EEG Device, Multi-Electrode Wearable EEG Device, and Head-Mounted Gyroscope

Loading...
Thumbnail Image

Files

umdRoute.pdf (895.76 KB)
No. of downloads: 1084

Publication or External Link

Date

2016-05

Citation

Abstract

Drowsy driving impairs motorists’ ability to operate vehicles safely, endangering both the drivers and other people on the road. The purpose of the project is to find the most effective wearable device to detect drowsiness. Existing research has demonstrated several options for drowsiness detection, such as electroencephalogram (EEG) brain wave measurement, eye tracking, head motions, and lane deviations. However, there are no detailed trade-off analyses for the cost, accuracy, detection time, and ergonomics of these methods. We chose to use two different EEG headsets: NeuroSky Mindwave Mobile (single-electrode) and Emotiv EPOC (14- electrode). We also tested a camera and gyroscope-accelerometer device. We can successfully determine drowsiness after five minutes of training using both single and multi-electrode EEGs. Devices were evaluated using the following criteria: time needed to achieve accurate reading, accuracy of prediction, rate of false positives vs. false negatives, and ergonomics and portability. This research will help improve detection devices, and reduce the number of future accidents due to drowsy driving.

Notes

Rights